<ErrorNumber>15374</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Drum vacuum level too high, threshold = &lt;n&gt;, current level = &lt;n&gt; (index word)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error is likely due to the media not being loaded properly.  Select
RESUME from the workstation dialog box.  If that doesn't correct the problem,
select CANCEL IMAGE from the workstation dialog box.  You may need to open
the proofer and remove the media if it isn't ejected on
it's own. If CANCEL IMAGE is not available, select CLEAR and make sure that
you remove all media other than the carrier in the machine.
If this problem recurs frequently contact Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
If the machine already has media on the drum of a similar type to that
which is currently being loaded, remove the loaded media and
continue.  Otherwise, when the problem occurs, determine if the media
is loaded correctly.  If it is not, watch a few load/unload cycles with
the doors open and try to determine what is going wrong.  If the media
is being loaded correctly, then the vacuum sensors are not working
properly or the vacuum thresholds are mis-adjusted.  You can check
the vacuum sensor readings using the "proof" command.
Additionally, at the end of the error message, an index word is printed to help
determine which threshold in NVS is being used when error occurs.
</text></DescriptionText>
<DescriptionText><UnnumberedList>
<ListItem><Text>(c_unload_4) : dvct</Text></ListItem>
<ListItem><Text>(c_unload_6) : dvct</Text></ListItem>
<ListItem><Text>(load_3a) : dvdt</Text></ListItem>
<ListItem><Text>(load_3b) : dvrt</Text></ListItem>
<ListItem><Text>(load_6b) : dvdt</Text></ListItem>
<ListItem><Text>(load_9b) : dvdt</Text></ListItem>
<ListItem><Text>(load_11b) : dvdt</Text></ListItem>
<ListItem><Text>(load_12a) : dvdt</Text></ListItem>
<ListItem><Text>(unload_0b) : dvdt</Text></ListItem>
<ListItem><Text>(unload_4) : dut</Text></ListItem>
<ListItem><Text>(unload_10a) : dvdt</Text></ListItem>
<ListItem><Text>(unload_10b) : dvrt</Text></ListItem>
</UnnumberedList></DescriptionText>
<DescriptionText><text>
Please make sure that the error is NOT due to mechanical alignment before adjusting
NVS thresholds.
</text></DescriptionText>
</ServiceInformation>
<ServiceInformation>
<DescriptionText><text>
The sensors can be over-ridden using the "alproof vsi" parameter.  This
will allow the machine to operate, but in a much slower and more dangerous
manner. In this state, the machine should only be used if absolutely
necessary and if it will be fixed very soon.  When the sensors are disabled,
the machine is running "blind", so it could incur additional damage if
used.  Use extreme caution.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The machine checks vacuum levels on the drum before loading media
to ensure that there is nothing already on the drum.  The error is most
likely due to the media being loaded incorrectly.  It is
also possible that the drum vacuum sensor is not working properly
or the thresholds are not set properly.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/proof.xml</LinkAddress><LinkTitle>Command: proof</LinkTitle></Link>
<Link><LinkAddress>../commands/pload.xml</LinkAddress><LinkTitle>Command: pload</LinkTitle></Link>
<Link><LinkAddress>../commands/punload.xml</LinkAddress><LinkTitle>Command: punload</LinkTitle></Link>
<Link><LinkAddress>../nvs/alproof_cfg_vsi.xml</LinkAddress><LinkTitle>NVS: alproof vsi</LinkTitle></Link>
<Link><LinkAddress>../nvs/alproof_cal_rvgt.xml</LinkAddress><LinkTitle>NVS: alproof rvgt</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvct.xml</LinkAddress><LinkTitle>NVS: proof dvct</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvrt.xml</LinkAddress><LinkTitle>NVS: proof dvrt</LinkTitle></Link>
<Link><LinkAddress>../nvs/proof_cal_dvdt.xml</LinkAddress><LinkTitle>NVS: proof dvdt</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:05 2008 PST
</Updated>
<Links>
</Links>
</Error>